Webinar

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Long Island, NY – 5.2.24

This class is designed for installation and service personnel. Course Outline:• Greenspeed / Extreme,• 18/19/0 VS Installation Greenspeed / Extreme,• 18/19/0 VS Set Up and Operation• 2-Stage Outdoor Units• FE / FV Fan coil Setup and Operation• User Interface Startup / Using it as a service tool• Troubleshooting Codes Explained• Troubleshooting Procedures• Tools Necessary for […]

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Long Island, NY – 5.2.24 Read More »

Carrier Bryant Ductless Installation – In-person – Dedicated – Troy, NY – 2.27.2024

Dedicated Family Danz In-person: 8hrs. 8:00AM to 4:30PM, Link to download books provided. This class is designed for sales, installation and service personnel. Course Outline:• Necessary Tools• Ductless single and Multi-zone Installation• Best Practices• Ductless Controls• Troubleshooting Procedures NATE Class ID 8504-0013

Carrier Bryant Ductless Installation – In-person – Dedicated – Troy, NY – 2.27.2024 Read More »

Carrier Bryant Ductless Installation – In-person – Dedicated – 2/14/2024

Dedicated Yuhan In-person: 8hrs. 8:00AM to 4:30PM, Link to download books provided. This class is designed for sales, installation and service personnel. Course Outline:• Necessary Tools• Ductless single and Multi-zone Installation• Best Practices• Ductless Controls• Troubleshooting Procedures NATE Class ID 8504-0013

Carrier Bryant Ductless Installation – In-person – Dedicated – 2/14/2024 Read More »

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Dedicated – Utica, NY – 5.22.24

Dedicated Collis This class is designed for installation and service personnel. Course Outline:• Greenspeed / Extreme,• 18/19/0 VS Installation Greenspeed / Extreme,• 18/19/0 VS Set Up and Operation• 2-Stage Outdoor Units• FE / FV Fan coil Setup and Operation• User Interface Startup / Using it as a service tool• Troubleshooting Codes Explained• Troubleshooting Procedures• Tools

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Dedicated – Utica, NY – 5.22.24 Read More »

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Dedicated – Flemington, NJ – 1.30.24

This class is designed for installation and service personnel. Course Outline:• Greenspeed / Extreme,• 18/19/0 VS Installation Greenspeed / Extreme,• 18/19/0 VS Set Up and Operation• 2-Stage Outdoor Units• FE / FV Fan coil Setup and Operation• User Interface Startup / Using it as a service tool• Troubleshooting Codes Explained• Troubleshooting Procedures• Tools Necessary for

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Dedicated – Flemington, NJ – 1.30.24 Read More »

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Dedicated – Rochester, NY – 2.7.24

This class is designed for installation and service personnel. Must pass Quiz class to receive course credit. Course Outline:• Greenspeed / Extreme,• 18/19/0 VS Installation Greenspeed / Extreme,• 18/19/0 VS Set Up and Operation• 2-Stage Outdoor Units• FE / FV Fan coil Setup and Operation• User Interface Startup / Using it as a service tool•

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Dedicated – Rochester, NY – 2.7.24 Read More »

Carrier Bryant Ductless Equipment Selection Course with ccASHP Sizing and Design – Webinar – 1.16.24

Webinar: 4.5hr. Class, Link to download books provided. This class is designed for sales, installation and service personnel. Required Training for NYS Clean Heat/NEEP, EnergizeCT and MassSave. Course Outline: • Brief Product Overview • Ductless Control Strategies • Applying Residential Load Calculations Must pass Quiz class to receive course credit. NATE Class ID 8504-0012

Carrier Bryant Ductless Equipment Selection Course with ccASHP Sizing and Design – Webinar – 1.16.24 Read More »

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Edison Dedicated – 12.6-7.2023

This class is designed for installation and service personnel. Course Outline:• Greenspeed / Extreme,• 18/19/0 VS Installation Greenspeed / Extreme,• 18/19/0 VS Set Up and Operation• 2-Stage Outdoor Units• FE / FV Fan coil Setup and Operation• User Interface Startup / Using it as a service tool• Troubleshooting Codes Explained• Troubleshooting Procedures• Tools Necessary for

Carrier Bryant Infinity Evolution Variable Speed 2-Stage Systems – In-person – Edison Dedicated – 12.6-7.2023 Read More »

Carrier/Bryant Infinity/Evolution Variable Speed/2-Stage Systems – In-person – West Caldwell, NJ – 5.16.24

This class is designed for installation and service personnel. Course Outline:• Greenspeed / Extreme,• 18/19/0 VS Installation Greenspeed / Extreme,• 18/19/0 VS Set Up and Operation• 2-Stage Outdoor Units• FE / FV Fan coil Setup and Operation• User Interface Startup / Using it as a service tool• Troubleshooting Codes Explained• Troubleshooting Procedures• Tools Necessary for

Carrier/Bryant Infinity/Evolution Variable Speed/2-Stage Systems – In-person – West Caldwell, NJ – 5.16.24 Read More »

Carrier/Bryant Infinity/Evolution Variable Speed/2-Stage Systems – In-person – Tom’s River, NJ – 5.9.24

This class is designed for installation and service personnel. Course Outline:• Greenspeed / Extreme,• 18/19/0 VS Installation Greenspeed / Extreme,• 18/19/0 VS Set Up and Operation• 2-Stage Outdoor Units• FE / FV Fan coil Setup and Operation• User Interface Startup / Using it as a service tool• Troubleshooting Codes Explained• Troubleshooting Procedures• Tools Necessary for

Carrier/Bryant Infinity/Evolution Variable Speed/2-Stage Systems – In-person – Tom’s River, NJ – 5.9.24 Read More »

Scroll to Top